Electrostatic Force Microscopy / Electrical Measurement AFM Probes

Electrostatic Force Microscopy / Electrical Measurement AFM Probes

Most popular in this category

PPP-EFM
PPP-EFM
  • PtIr5 coated AFM probe
  • C = 2.8 N/m; fo = 75 kHz

PointProbe® Plus Platinum-Iridium coated

PointProbe® Plus Platinum-Iridium coated
PPP-CONTPt
  • Contact Mode
  • PtIr5 coated AFM probe
  • C = 0.2 N/m; fo = 13 kHz
PPP-CONTSCPt
  • Contact Mode
  • PtIr5 coated AFM probe
  • C = 0.2 N/m; fo = 25 kHz
PPP-NCHPt
  • Non-Contact High frequency
  • PtIr5 coated AFM probe
  • C = 42 N/m; fo = 330 kHz
PPP-NCSTPt
  • Non-Contact Soft Tapping
  • PtIr5 coated AFM probe
  • C = 7.4 N/m; fo = 160 kHz
PPP-EFM
  • PtIr5 coated AFM probe
  • C = 2.8 N/m; fo = 75 kHz

Platinum Silicide AFM Probes

Platinum Silicide AFM Probes
PtSi-CONT
  • Contact Mode
  • PtSi coated AFM probe
  • C = 0.2 N/m; fo = 13 kHz
PtSi-FM
  • Force Modulation Mode
  • PtSi coated AFM probe
  • C = 2.8 N/m; fo = 75 kHz
PtSi-NCH
  • Non-Contact High frequency
  • PtSi coated AFM probe
  • C = 42 N/m; fo = 330 kHz

Conductive Diamond coated

Conductive Diamond coated
CDT-CONTR
  • Contact Mode
  • Conductive Diamond coated AFM Tip
  • Back side Reflex coating
  • C = 0.5 N/m; fo = 20 kHz
CDT-FMR
  • Force Modulation Mode
  • Conductive Diamond coated AFM Tip
  • Back side Reflex coating
  • C = 6.2 N/m; fo = 105 kHz
CDT-NCHR
  • Non-Contact High frequency
  • Conductive Diamond coated AFM Tip
  • Back side Reflex coating
  • C = 80 N/m; fo = 400 kHz
CDT-NCLR
  • Non-Contact Long AFM cantilever
  • Conductive Diamond coated AFM Tip
  • Back side Reflex coating
  • C = 72 N/m; fo = 210 kHz

AdvancedTEC™

AdvancedTEC™
ATEC-CONTPt
  • Advanced AFM Tip at the End of the
    Cantilever™
  • real AFM tip visibility from top
  • Contact Mode
  • PtIr5 coated AFM probe
  • C = 0.2 N/m; fo = 15 kHz
ATEC-CONTAu
  • Advanced AFM Tip at the End of the
    Cantilever™
  • real AFM tip visibility from top
  • Contact Mode
  • Au coating (both sides)
  • C = 0.2 N/m; fo = 15 kHz
ATEC-NCPt
  • Advanced AFM Tip at the End of the
    Cantilever™
  • real AFM tip visibility from top
  • Non-Contact
  • PtIr5 coated probe
  • C = 45 N/m; fo = 335 kHz
ATEC-NCAu
  • Advanced AFM Tip at the End of the
    Cantilever™
  • real AFM tip visibility from top
  • Non-Contact
  • Au coating (both sides)
  • C = 45 N/m; fo = 335 kHz
ATEC-FMAu
  • Advanced AFM Tip at the End of the
    Cantilever™
  • real AFM tip visibility from top
  • Force Modulation Mode
  • Au coating (both sides)
  • C = 2.8 N/m; fo = 85 kHz
ATEC-EFM
  • Advanced AFM Tip at the End of the
    Cantilever™
  • real AFM tip visibility from top
  • PtIr5 coated AFM probe
  • C = 2.8 N/m; fo = 85 kHz

PointProbe® Plus Gold coated

PointProbe® Plus Gold coated
PPP-NCHAu
  • Non-Contact High frequency
  • Au coating (both sides)
  • C = 42 N/m; fo = 330 kHz
PPP-NCLAu
  • Non-Contact Long AFM cantilever
  • Au coating (both sides)
  • C = 48 N/m; fo = 190 kHz
PPP-NCSTAu
  • Non-Contact Soft Tapping
  • Au coating (both sides)
  • C = 7.4 N/m; fo = 160 kHz
PPP-CONTAu
  • Contact Mode
  • Au coating (both sides)
  • C = 0.2 N/m; fo = 13 kHz
PPP-FMAu
  • Force Modulation Mode
  • Au coating (both sides)
  • C = 2.8 N/m; fo = 75 kHz